Frontpage Slideshow (version 2.0.0) - Copyright © 2006-2008 by JoomlaWorks
title

Products

Hofatex® SysTem IA

Hofatex SysTherm IAA high quality insulation board for internal thermal insulation; it is suitable for plastering, as an underlayer for mineral- and clay-based plasters and for all types of refined plastering systems. The board is especially appropriate for reconstructed and historic facades.

λD= 0.041 W/(m.K)
Thickness: 40, 60, 80, 100 mm
Dimensions: 2600x1220 mm, 590x1300 mm

Use:

  • Insulation panels suited to internal thermal insulation of solid, sandwich- or framework- constructed buildings
  • High-build coating or wallpaper can be applied
  • Use in accordance with DIN V 4108/10:2002: DI, WH, WI, WTR

Technical parameters:

Produced in accordance with DIN EN 13171

Board designation WF-EN 13171-T4-CS(10/Y)40-TR15-WS1,0
Thickness [mm] 40 60 80 100
Thermal resistance R D [m² .K/W] 0,98 1,47 1,96 2,44
Equivalent diffusion thickness s d [m] 0,20 0,30 0,40 0,50
Heat conductivity λD - claimed [W/m.K] 0,041
Heat conductivity λ - calculated [W/m.K] 0,042
Density [kg/m³] 170
Thermal capacity c [kJ/kg.K] 2100
Diffusion resistance factor μ 5
Edge tongue-and-groove, smooth
Flammability class EN 13501 - 1 E
Absorption [kg/m² ] 1
Tensile strength [kPa] 15/30
Compression strength [kPa] 40/100

Packing:

Board thickness (mm) P+D 20 40 60 80 hladká 40 60 80 100
Boards per pallet 52 36 26 22 26 18 13 11
Weight per pallet (kg) 271 282 271 287 561 582 561 593
Cubic metres per pallet
Square metres per pallet less tongues 39,9 27,6 19,9 16,9 82,5 57,1 41,2 34,9
Square metres per pallet with tongues 42,4 29,3 21,2 17,9

Storage, handling and laying

  • Store panels in a dry area and lay them down dry
  • Protect the edges against damage
  • Lay vertically beginning at the corner of the room; the panel groove must be lined up to the adjacent wall
  • Lay the panels as tightly as possible with the smallest gap possible
  • Cut panels with ordinary cutting tools - use of suction equipment is recommended
  • Caulk places where screws or staples are set and join individual panels together at the seams with covering tape
TRADE FAIRS  2010 - 2011