Hofatex® UD

Tongue-and-groove panels open for diffusion, which can be used as a layer to reinforce the main insulation - under the roof or as the external layer in the wood-framing of enclosure walls. It has enhanced water resistance.

λD= 0,049 W/(m.K)
Thickness: 22, 35, 52 ,60, 80, 100 mm
Dimensions: 580x2500 mm

Use:

  • External insulation layer
  • Panels under the roof - secures hydro-insulation in pent roofs
  • Temporary roof-decking for a maximum of 3 months
  • External sheathing of framework and stonework-constructed enclosure walls
  • Use in accordance with DIN V 4108/10:2002: DAD, DAA, WAB, WAP, WH

Technical parameters:

Produced in accordance with DIN EN 13171

Board designation WF-EN 13171-T4-CS(10/Y)100-TR100-WS1,0
Thickness [mm] 22 35 52 60 80 100
Thermal resistance R D [m² .K/W] 0,45 0,72 1,07 1,23 1,64 2,05
Equivalent diffusion thickness s d [m] 0,11 0,18 0,26 0,30 0,40 0,50
Heat conductivity λD - claimed [W/m.K] 0,049
Heat conductivity λ - calculated [W/m.K] 0,050
Density [kg/m³] 260
Thermal capacity c [kJ/kg.K] 2100
Diffusion resistance factor μ 5
Edge tongue-and-groove
Flammability class EN 13501 - 1 E2
Absorption [kg/m² ] 1
Tensile strength [kPa] 50
Compression strength [kPa] 100

Packing:

Board thickness (mm) 22 35 52 60 80 100
Boards per pallet 100 62 42 36 26 22
Weight per pallet (kg) 829 818 823 814 549 581
Cubic metres per pallet 3,19 3,15 3,17 3,13 3,02 3,19
Square metres per pallet less tongues 145,0 89,9 60,9 52,2 26,4 22,3
Square metres per pallet with tongues 151,5 93,9 64,0 54,9 27,9 23,6

Storage, handling and laying:

  • Store panels in a dry area and lay them down dry
  • Protect the edges against damage
  • Lay panels with the tongues facing upwards
  • Where the roof has an angle of less than 20°, glue the seams of the boards together
  • For each type of thickness, keep the boards the following maximum distance away from the beams:
  • 22 mm – 85 cm
  • 35 mm – 95 cm
  • 52 mm – 100 cm
  • 60 mm – 105 cm
  • 80 mm - 110 cm
  • 100 mm – 115 cm
  • Keep the panels away from the rafter beams
  • After laying the panels, lath and contra-lath them as soon as possible
TRADE FAIRS  2010 - 2011
24. 27.2.2010
Kolín
Nemecko
dach
hofa_lupa foto
25. – 28.2.2010
PVA – Letňany
Praha
drevo
hofa_lupa foto
17. 22.1.2011
Mníchov
bau_mnichov
hofa_lupa foto
24. - 27. 2. 2011
Praha - Holešovice
Praha 2011
hofa_lupa foto